Parameters
The Tri-State Conduit BFM supports signals that interface to multiple external memory devices.
Table 12-1: Tri-State Conduit BFM Parameter Settings
DescriptionLegal ValuesDefault ValueOption
Specifies the role name of each port.Any stringN/ARole
Specifies the port width.1–10241Width
Specifies an input port.0 or 11USE_INPUT
Specifies an output port.0 or 11USE_OUTPUT
Specifies an output enable port.0 or 11USE_OUTPUTENABLE
Specifies the maximum transactions of
data while request and grant signals are
asserted. The value is constraint by the
number of roles.
N/A1024MAX_MULTIPLE_
TRANSACTION
Related Information
• Avalon Interface Specifications
• Avalon Tri-State Conduit Components User Guide
Tri-State Conduit BFM API
event_all_transactions_complete()
event_all_transactions_complete()Prototype:
Verilog HDL: N.A.
VHDL: None
Arguments:
voidReturns:
Notifies the testbench that all commands have completed.Description: