SystemVerilog AXI3 and AXI4 Monitor BFMs
get_write_data_ready()
September 2013
get_write_data_ready()
This blockingAXI4 task returns the write data ready value of the WREADY signal using the
ready argument. It will block for one ACLK period.
AXI3 BFM
The get_write_data_ready() task is not available in the AXI3 BFM.
AXI4 Example
// Get the value of the WREADY signal
bfm.get_write_data_ready();
Prototype
task automatic get_write_data_ready
(
output bit ready
);
Arguments ready
The value of the WREADY signal.
Returns
None