Altera DSP Development Kit, Cyclone II Edition Getting St Uživatelský manuál Strana 20

  • Stažení
  • Přidat do mých příruček
  • Tisk
  • Strana
    / 32
  • Tabulka s obsahem
  • KNIHY
  • Hodnocené. / 5. Na základě hodnocení zákazníků
Zobrazit stránku 19
2–10 Getting Started User Guide Altera Corporation
DSP Development Kit, Cyclone II Edition August 2006
Connect the Cables to the Board & PC
Connecting the SMA Cable
After attaching the SLP-50 (or other) anti-aliasing filter to one end of the
the SMA cable, connect the SMA cable to the D/A and A/D connectors
on the Cyclone II development board:
The SMA D/A output converter DAC CHANNEL A (J31)
The SMA A/D input converter ADC CHANNEL A (J32)
Figure 2–4 shows the cable and the SLP-50 anti-aliasing filter installed as
required in “Performing the A/D & D/A Converter Performance Test”
on page 2–16.
Figure 2–4. SMA Cable & SLP-50 Filter Installed to Connect DAC CHANNEL A (J31) with ADC CHANNEL A
(J32)
Zobrazit stránku 19
1 2 ... 15 16 17 18 19 20 21 22 23 24 25 ... 31 32

Komentáře k této Příručce

Žádné komentáře