A–4 Appendix A: Clear Box Generator
Clear Box Generator Options
ALTDLL and ALTDQ_DQS Megafunctions User Guide © February 2012 Altera Corporation
DLL_OFFSET_CTRL_A_
USE_OFFSET
String No Available values are TRUE and FALSE. It determines the
output of the
dll_offset_ctrl_a_offsetctrlout[5..0]
output bus. If set to TRUE, then depending on whether the
dll_offset_ctrl_a_addnsub input is asserted or
not, the phase offset specified on the
dll_offset_ctrl_a_offset[5..0]input bus is
added or subtracted from the DLL delay setting output to get
the dll_offset_ctrl_a_offsetctrlout[5..0]
output. If set to FALSE, the phase offset specified by the
DLL delay setting to get the
dll_offset_ctrl_a_offsetctrlout[5..0]
output. If omitted, the default is FALSE.
DLL_OFFSET_CTRL_B_
STATIC_OFFSET
String No This is a Gray-coded signed integer expressed as a string
with a range from –63 to 63. If the
DLL_OFFSET_CTRL_B_USE_OFFSET parameter is set
to FALSE, the value is added to the DLL delay-setting value
and appears as output on the
dll_offset_ctrl_a_offsetctrlout[5..0]
output bus. If the DLL_OFFSET_CTRL_B_USE_OFFSET
parameter is set to TRUE, ignore this value. The default
value is 0.
DLL_OFFSET_CTRL_B_
USE_OFFSET
String No Available values are TRUE and FALSE. It determines the
output of the
dll_offset_ctrl_b_offsetctrlout[5..0]
output bus. If set to TRUE, then depending on whether the
dll_offset_ctrl_b_addnsub input is asserted or
not, the phase offset specified on the
dll_offset_ctrl_b_offset[5..0]input bus is
added or subtracted from the DLL delay setting output to get
the dll_offset_ctrl_b_offsetctrlout[5..0]
output. If set to FALSE, the phase offset specified by the
DLL delay setting to get the
dll_offset_ctrl_b_offsetctrlout[5..0]
output. If omitted, the default is FALSE
INPUT_FREQUENCY String Yes This is the frequency of the clock connected to the clk
input port. Check this parameter value to ensure that it falls
within a valid range. This field is required and defaults to 0.
You can specify a duration by placing a time unit after the
value (for example, 2.5 ns). The value is in floating-point
format with no decimal point limit.
JITTER_REDUCTION String No Available values are TRUE and FALSE. If set to TRUE, the
jitter reduction circuit is enabled on the
dll_delayctrlout[5..0], and
dll_offset_ctrl_a_offsetctrlout[5..0]or
dll_offset_ctrl_b_offsetctrlout[5..0]
outputs and the DLL may require up to 1,024 clock cycles to
lock. If set to FALSE, the jitter reduction circuit is disabled
and the DLL only requires up to 256 clock cycles to lock. If
omitted, the default is FALSE.
Table A–1. ALTDLL Megafunction Parameters (Part 2 of 3)
Parameter Name Type Required Description
Zobrazit stránku 104