Chapter 4: Development Board Setup 4–7
Factory Default Switch Settings
June 2011 Altera Corporation Stratix IV E FPGA Development Kit User Guide
f For more information about the FPGA board settings, refer to the Stratix IV E FPGA
Development Board Reference Manual.
J21 VCC_VCCL_SEL
This jumper has the following options:
Installing the shunt on pins 1 and 2 sets VCC and VCCL to 0.9 V.
Installing the shunt on pins 2 and 3 sets VCC and VCCL to 1.1 V.
Removing the shunt sets VCC and VCCL to 0.6 V.
Always keep a shunt installed on pins 1 and 2 only. The current version
of the Stratix IV E device requires 0.9 V.
Installed on
pins 1 and 2
J28 RLD_ZQ_IMPED
To use the RLDRAM II impedance drive jumpers, set the mode
register. When the mode register is not set, the RLDRAM II output
impedance is 50 Ω. The RLDRAM II impedance drive jumpers have the
following options:
Installing the shunt on pins 1 and 2 sets the RLDRAM II output
impedance to the maximum value possible.
Installing the shunt on pins 3 and 4 sets the RLDRAM II output
impedance to 50 Ω.
Installing the shunt on pins 5 and 6 sets the RLDRAM II output
impedance to 60 Ω.
Installing more than one shunt might cause damage to the device.
Not installed
Table 4–4. Jumper Settings (Part 2 of 2)
Board
Reference
Board
Label
Function
Default
Shunt Position